Single event sensitivity |
Item
| Unit
| Proposal
| Revised MC
| Measured
| Value |
Muon stopping rate
| s-1
| 0.3 * 108
| 0.25 * 108
| 1 * 108 5)
| |
Measurement time
| PSI beam weeks (= 4*105s)
| 65
| 100
| -
| |
Solid angle
| sr/4Pi
| 0.09
| -
| -
| |
Positron detection efficiency
| 1
| 0.90
| 0.65
| -
| |
Gamma detection efficiency
| 1
| 0.6
| 0.6
| 0.46)
| |
Event selection efficiency
| 1
| 0.7
| 0.7
| -
| |
Single event sensitivity
|
| *10^ |
|
Accidental background rate |
Resolution
| Unit
| Proposal
| Revised MC
| Measured
| Value |
Photon Detector |
Energy
| % (FWHM) @ 52.8 MeV/c2
| 4.0
| 4.3
| 56)
| |
Timing
| ps (FWHM)
| 100
| 100
| 1506)
| |
Position
| mm (FWHM)
| 9
| 10
| 96)
| |
Positron Detector |
Energy
| % (FWHM) @ 52.8 MeV/c2
| 0.8
| 0.8
| -
| |
Timing
| ps (FWHM)
| 100
| 100
| 1001)
| |
Angle
| mrad (FWHM)
| 9
| 10.5
| -
| |
Muon decay position
| mm (FWHM)
| 2.1
| -
| -
| |
Reference values |
Photon yield/muon (y > y min)
| Pure number
| 5 * 10-7
| 5 * 10-7
| -
| |
Minimum y value
| Pure number
| 0.965
| 0.965
| -
| |
Combined values |
Relative Timing
| ps (FWHM)
|
| |
Gamma Angle 2)
| mrad (FWHM)
|
| |
Relative Angle
| mrad (FWHM)
|
| |
Accidental Background Rate 3)
|
| *10^ |
Number of expected Background Events
|
| |
90% C.L. sensitivity 4)
|
| *10^ |